Dispersant NNO for Concrete: How It Works, Grades and Dosage

Dispersant NNO for Concrete: How It Works, Grades and Dosage — diagram

Dispersant NNO is the sodium salt of naphthalene sulfonate formaldehyde condensate. In Chinese it is often called sodium methylene bis-naphthalene sulfonate. In concrete, the same chemistry is sold as SNF, also called PNS, FDN or naphthalene superplasticizer. “NNO” is the name used mostly in the dye and textile trade, while “SNF” is the name used in construction. Chemically they are the same family. The differences between products lie in molecular weight, sodium sulfate content and purity, which is why concrete producers specify grades by sulfate content and cement-paste fluidity.

How NNO/SNF works in concrete

  • Adsorption and repulsion: the sulfonate groups adsorb on cement grains and give them a strong negative charge. The grains repel each other, flocs break up, and water trapped inside the flocs is released.
  • Water reduction: the same slump is reached with much less mixing water. A lower water–cement ratio gives denser paste, higher strength and lower permeability.
  • Low air and little retardation: unlike lignosulfonate, naphthalene sulfonate entrains little air and retards setting only slightly. That is why it suits early-strength and precast work.
  • Slump loss: because the dispersion is mainly electrostatic, workability falls faster than with polycarboxylate (PCE). In ready-mix concrete, NNO/SNF is often blended with a retarder such as sodium gluconate or lignosulfonate.

Performance in standard tests

Test (concrete with admixture vs. control)Typical requirementGAC-SNF-5 result
Water reduction≥ 14%17%
Air content≤ 3.0%2.0%
Compressive strength ratio, 1 day≥ 140%165%
Compressive strength ratio, 3 days≥ 130%155%
Compressive strength ratio, 7 days≥ 125%135%
Compressive strength ratio, 28 days≥ 120%130%
Shrinkage ratio, 28 days≤ 135%87%

Source: Green Agrochem GAC-SNF-5 TDS (performance test data; requirements follow the Chinese concrete admixture standard GB 8076). Results depend on cement, aggregates and mix design, so treat them as the performance of a qualified test mix, not a guaranteed value for every project.

Which grade to use

ParameterSNF 5% gradeSNF 18% gradeSNF powder (GAC-SNF-P)
Sodium sulfate5% max18% max10% max
Solids91% min—95% min
Chloride0.4% max0.5% max< 200 ppm
Cement paste fluidity220 mm min210 mm—
pH7–9—6.5–8.5

CAS 36290-04-7. Values from current Green Agrochem TDS documents.

  • Low-sulfate grades (5%) are preferred for liquid admixtures, because sodium sulfate can crystallise out of concentrated solutions in cold weather, and for cement-sensitive mixes.
  • Higher-sulfate grades (18%) cost less and are common in powder blends and general concrete.
  • Dispersant NNO grades (A: disperse power 95% min, Na2SO4 5% max; B: disperse power 90% min, Na2SO4 18% max; C: Na2SO4 22% max; high-purity grade with free formaldehyde < 50 ppm) can be used where a supplier stocks NNO rather than SNF. Compare them on sodium sulfate, fluidity and chloride, not on the name.

Dosage and use

  • Typical dosage: 0.5–1.0% by weight of cementitious material, with 0.75% as the usual first trial (GAC-SNF-5 TDS).
  • Add as powder or as a pre-dissolved solution. Adding it with or after part of the mixing water usually gives better dispersion than adding it to dry cement.
  • Run trial mixes against a control: slump or flow at 0 and 60 minutes, air content, setting time and compressive strength at 1, 3, 7 and 28 days.
  • Check compatibility with the actual cement. Cements with low soluble alkali sulfate or high C3A can show rapid slump loss with naphthalene superplasticizers.

Typical uses

  • Precast and prestressed elements, where high early strength and low air are wanted.
  • High-strength and pumped concrete.
  • Steam-cured products such as pipes, piles and railway sleepers.
  • Base material for liquid admixture formulations, often blended with retarders.
  • Gypsum and cement-based dry mixes, and oil-well cement slurries as a dispersant.

Classification by standards

In ASTM C494, naphthalene superplasticizers are qualified as Type F (high-range water-reducing) or Type G (high-range water-reducing and retarding). These types require at least 12% water reduction. EN 934-2 has equivalent high-range water-reducing classes, and China uses GB 8076.

Handling

NNO/SNF powder is hygroscopic. Keep bags sealed and dry, and avoid inhaling dust. Wear gloves and goggles when handling powder or solutions. Follow the SDS.

Frequently asked questions

Is Dispersant NNO the same as SNF?

They belong to the same chemical family, sodium naphthalene sulfonate formaldehyde condensate, and share the CAS numbers used for this condensate (commonly 36290-04-7; 9084-06-4 is also cited). Products differ in degree of condensation, sodium sulfate content and purity. For concrete, choose by cement-paste fluidity, sodium sulfate and chloride on the TDS, and confirm with trial mixes.

Does NNO corrode reinforcing steel?

Naphthalene superplasticizers are essentially chloride-free. Our SNF TDS limits chloride to 0.4% max (5% grade), and the powder grade is below 200 ppm. Check the chloride limit required by your concrete standard and calculate the total chloride from all mix ingredients.

Can NNO be used with polycarboxylate (PCE)?

Mixing them directly in one admixture can cause rapid loss of workability. If both must be used in a plant, use separate dosing and test the combination before use.

Why does my concrete lose slump quickly with NNO?

The usual causes are: a cement with low soluble sulfate or high C3A, high temperature, or adding the admixture too early to dry materials. Remedies include delayed addition, a retarder (sodium gluconate or lignosulfonate), or a split dose.

Is NNO suitable for self-compacting concrete?

It can produce flowing concrete. However, self-compacting concrete normally needs the higher water reduction and slump retention of PCE, together with a viscosity-modifying agent.